[ Log In ]

 

Nuclear Incident Response Program

Turbo FRMAC

Turbo FRMAC 2023
Release Notes

Turbo FRMAC 11.3.1 (2023)

(102509) Fixed an error that occurred when setting up the briefing product of the Projected Public Dose Over Time calculation that prevented opening a blank calculation. Now the calculation initializes and works as intended.

Turbo FRMAC 11.3.0 (2023)

(101867) Major update of provided default mixtures for use in Turbo FRMAC. Please reference Mixture Manager 4.0 release notes for more information on the default mixture changes.

(102095) Added FRMAC Assessment Manual Volume 3 access through Mixture Manager.

(12138) Combined the Solid and Liquid Ingestion Calculations, allowing users to toggle between entering a volume or mass for the input measurements.

(102019) Added default selections for the Building Protection Factor options described in Table 6-2, Appendix C of the FRMAC Assessment Manual Volume 2.

(22718) Added a results button to show the Intervention Level calculation in the Ingestion DRL calculations.

(12150) Added a warning to notify the user when duplicate time phase settings are present in the calculation.

(100827) Added Mixture Total and Percent Contribution information to the Dose Rollup Tool when the table is copied to Excel or the Clipboard.

(99135) Scaling a mixture now does not reapply any equilibrium adjustment after scaling the mixture. Fixes a bug where scaling an aged mixture would cause the mixture to revert back to initial equilibrium conditions.

(101231) Removed all Return to Grazing calculations due to changes to the Meat and Milk DRL methods, implemented in Turbo FRMAC 2020 v10.1.0, where Time to Grazing was added as an input to the DRL methods and therefore can no longer be calculated as an output.

(102076) Added units to the Excel output headers for chart tables such as those in the Projected Return Time calculation.

(101419) Renamed the "ICRP & FDA Settings" Panel to "ICRP Guidance" in the food ingestion dose calculations and projected contamination in food calculations.

(101877) The uncertainty analysis tool was updated to allow non-multiplier values when the user provides an inhalation dose coefficient and to summarize dose results by radionuclide instead of the parent in a decay chain. Inputs specified for a radionuclide apply to all instances of that radionuclides in the mixture (instead of just the parents of radionuclide chains).

(100886) Equilibrium and Scale menu options were disabled from calculations where they do not apply - the Crop, Meat, and Milk DRLs.

(101536) Renamed "Feed" transfer factor to "Forage" transfer factor to be consistent with the FRMAC Assessment Manual's naming conventions.

(101974) On the "New Calculation" panel, removed empty tool tip popups when hovering over calculations that do not have a defined tool tip.

(100065) Removed an incorrect warning for automatically set time phase settings in PAG emulation mode.

(100614) Fixed Exception that would occur for mixtures with over 300 radionuclides (Vector Comodification Exception). Now Turbo FRMAC can support mixtures that contain about 500 radionuclides.

(101662) Renamed some keyboard shortcut capabilities. Some keyboard shortcuts that only applied in certain situations were removed.

(101885) Parse error messages for input files were added to the uncertainty analysis tool.

SAND2023-04764W