Latest Version
Released:Jan 22, 2025
Description:
Single Installer Windows 64-bit Turbo FRMAC Version 12.1.0
SHA1 checksum value:
57471e9b402fd18171ed2e803dfc6338efc3bb6d
Notes
The Single Installer installs only the Turbo FRMAC application to your computer. Mixture Manager and Radionuclide Viewer can be launched from within Turbo FRMAC.
For information on silent, noninteractive installation of Turbo FRMAC, please refer to documentation on running an installer silently.
Overview
The Turbo FRMAC (TF) software automates the calculations described in Volume 2 of the FRMAC Assessment Manual. The manual upon which the software is based is unclassified and freely available by clicking here.
Using values generated by field samples, instrument readings, or computer dispersion models, TF assesses the generated results into values that are meaningful and actionable for a decision maker at a radiological emergency. TF provides calculated results to answer questions such as:
- Do radiation values exceed city, state, or federal limits?
- Should crops be destroyed or can they be utilized?
- Do residents need to be evacuated, sheltered in place, or should another action be taken?
- How long can emergency workers work in a given area?
The software uses formulas generated by the Environmental Protection Agency (EPA), Food and Drug Administration (FDA), and other federal agencies to generate field-observable values specific to the radiological event that can be used to determine where regulatory limit values are exceeded. TF calculates values that indicate:
- How long an emergency worker can work in the contaminated area during a radiological emergency?
- The dose received from drinking contaminated water or milk.
- The dose from eating contaminated food.
- The dose expected down or upwind of a given field sample.
- Other similar radiological health values.
TF is designed to help the decision maker in a radiological emergency understand the significance of the field sample results and modeling information, so that proper response actions can be implemented. The software provides information about the impacts a radiological emergency will have on people affected by the event. It is intended to aid the leadership in identifying the proper action needed in order to protect the public without causing widespread panic.
Turbo FRMAC is a member of RAMP. The purpose of the Radiation Protection Computer Code Analysis and Maintenance Program (RAMP) is to develop, maintain, improve, distribute and provide training on NRC-sponsored radiation protection and dose assessment computer codes. Training for Turbo FRMAC is available to RAMP members.
Features
- Formulas located in Volume 2 of the FRMAC Assessment Manual.
- Includes DCFPAK 2015, containing six different vintages of data with published coefficients ranging from years 1983 to 2015.
- A radionuclide viewer for viewing nuclide information, such as decay modes, and radionuclide decay chains.
- Integration with Radionuclide Mixture Manager which allows for importation of existing mixtures, ability to create and reuse mixtures, import mixtures from RASCAL, etc.
- Complex Particle Size Distribution that allows for calculation of values under realistic complex particle distribution scenarios.
- ICRP 60 with both true Monodispersed Dose Coefficients and Lognormal based coefficients.
- ICRP 107 radiation decay data.
- ICRP 56 (FDA) data for calculation of FDA DILs.
- Instrument Thresholds: allows indication of what energy levels field instruments can register to dynamically changes values to be consistent with instruments in use.
- Decay Curve Export: exports the decay curve of a mixture for importation into other software tools for further analysis. Charts allow for analysis of the decay curve inside TF.
- Ability to export table data to Microsoft Excel™.
- Ability to share calculations via email. Import and export calculations to TFX files.
- Internal Conversion Electrons: all beta analyses now include internal conversion electrons whose energy exceeds the user specified Instrument Threshold.
- Recent Mixtures: maintains a list of recently used mixtures for rapid and easy importation of commonly used mixtures.
- Ribbon-style interface to provide a Microsoft Office like experience.
Release Notes
Turbo FRMAC 12.1.0 (2025)
(GitLab 104196) Users can now set the maximum available memory for the application during the installation process, allowing the tool to handle larger mixtures than the default settings.
(FogBugz 103481) Created an export top dose contributors feature in the Dose Roll Up Tool. This feature reduces a mixture to a set of radionuclides that contribute a percentage of dose for time phases. The percentage, dose type, and time phases are user-defined.
(FogBugz 103308) Implemented OIL corrections for radionuclides with non-standard forms for inhalation and ingestion.
(FogBugz 103557) Fixed an error where meat and milk transfer factor references did not appear. Also fixed an issue maintaining user-entered values when the user toggles between user defined transfer factors and provided transfer factors.
(FogBugz 103843) Fixed an issue with saving and loading group transfer factor values.
(FogBugz 102405) Implemented option to only select and export total dose in the Excel Total Dose Export Tool.
(FogBugz 104085) Updated the Java version to Java 21 and related third party libraries.
SAND2023-04764W
Turbo FRMAC 12.0.0 (2024)
(101514) Implemented a new calculation category for calculating International Atomic Energy Agency (IAEA) Operational Intervention Levels (OILs) 1 and 2.
(101523) Added ICRP 88 fetus dose coefficients to the DCFPAK database for the OIL calculation. Also implemented a new way to store the DCFPAK location, allowing for the new application to reference a new DCFPAK while older applications can still reference the old location.
(101345) Added a resuspension factor multiplier input that uses values defined in the FRMAC manual to adjust resuspension values in a way that reflect physical conditions or impacts of mechanical effects.
(101497) Created a new Transfers Factors panel that allows the user to adjust the transfer factors for individual radionuclides. Transfer factor values were updated with values from PNNL-27926 and IAEA TRS 472.
(101497 Continued) Improved transfer factor panel for ingestion calculations that allows the user to more easily adjust values for individual radionuclides and specify reference.
(101497 Continued) Reorganized transfer factor data into a database that includes values for subcategories as specified in PNNL-27926.
(101497 Continued) Added ability to select crop subtype in Crop DRLs and Projected Crop Contamination Levels Calculations based on the values available in PNNL-27926.
(102433) Added the ability to specify plume and deposition inhalation dose coefficients of radionuclides in the uncertainty analysis tool input.
(102335) Added the option to select which calculation results to include in the Calculation Report wizard.
(101519) Corrected behavior on Occupancy Factor Panel where changes to Hours Partially in Contaminated Zone where not correctly distributed into the appropriate fields (Absent, Sheltered, Unsheltered).
(101637) Added word wrapping to the calculation report wizard.
(101594) Fixed issue where manual occupancy factors became uneditable after running a calculation.
(23293) Removed sorting ability from Ingestion RBE Values Table and Fraction of Diet Contaminated Table due to a sorting bug.
(102225) The use of the RAMS ID was mostly removed from the source code, but some parts were left in to keep the database set up the same.
(101758) Added export button to main file menu.
SAND2023-04764W
Turbo FRMAC 11.3.1 (2023)
(102509) Fixed an error that occurred when setting up the briefing product of the Projected Public Dose Over Time calculation that prevented opening a blank calculation. Now the calculation initializes and works as intended.
Turbo FRMAC 11.3.0 (2023)
(101867) Major update of provided default mixtures for use in Turbo FRMAC. Please reference Mixture Manager 4.0 release notes for more information on the default mixture changes.
(102095) Added FRMAC Assessment Manual Volume 3 access through Mixture Manager.
(12138) Combined the Solid and Liquid Ingestion Calculations, allowing users to toggle between entering a volume or mass for the input measurements.
(102019) Added default selections for the Building Protection Factor options described in Table 6-2, Appendix C of the FRMAC Assessment Manual Volume 2.
(22718) Added a results button to show the Intervention Level calculation in the Ingestion DRL calculations.
(12150) Added a warning to notify the user when duplicate time phase settings are present in the calculation.
(100827) Added Mixture Total and Percent Contribution information to the Dose Rollup Tool when the table is copied to Excel or the Clipboard.
(99135) Scaling a mixture now does not reapply any equilibrium adjustment after scaling the mixture. Fixes a bug where scaling an aged mixture would cause the mixture to revert back to initial equilibrium conditions.
(101231) Removed all Return to Grazing calculations due to changes to the Meat and Milk DRL methods, implemented in Turbo FRMAC 2020 v10.1.0, where Time to Grazing was added as an input to the DRL methods and therefore can no longer be calculated as an output.
(102076) Added units to the Excel output headers for chart tables such as those in the Projected Return Time calculation.
(101419) Renamed the "ICRP & FDA Settings" Panel to "ICRP Guidance" in the food ingestion dose calculations and projected contamination in food calculations.
(101877) The uncertainty analysis tool was updated to allow non-multiplier values when the user provides an inhalation dose coefficient and to summarize dose results by radionuclide instead of the parent in a decay chain. Inputs specified for a radionuclide apply to all instances of that radionuclides in the mixture (instead of just the parents of radionuclide chains).
(100886) Equilibrium and Scale menu options were disabled from calculations where they do not apply - the Crop, Meat, and Milk DRLs.
(101536) Renamed "Feed" transfer factor to "Forage" transfer factor to be consistent with the FRMAC Assessment Manual's naming conventions.
(101974) On the "New Calculation" panel, removed empty tool tip popups when hovering over calculations that do not have a defined tool tip.
(100065) Removed an incorrect warning for automatically set time phase settings in PAG emulation mode.
(100614) Fixed Exception that would occur for mixtures with over 300 radionuclides (Vector Comodification Exception). Now Turbo FRMAC can support mixtures that contain about 500 radionuclides.
(101662) Renamed some keyboard shortcut capabilities. Some keyboard shortcuts that only applied in certain situations were removed.
(101885) Parse error messages for input files were added to the uncertainty analysis tool.
SAND2023-04764W
Turbo FRMAC 11.2.0 (2023)
(101406) Updated the keyboard shortcuts in Turbo FRMAC.
(100371) Removed code associated with an outdated build and install process.
(100773) Created a new Calculation Report that identifies changed default input values and reports calculated results for the Public Protection DRL calculation. Report wizard includes fields for user to specify reasons for changes to default values.
(21226) Removed the time phase warning from the Nuclear Fallout Stay Time calculation when users cannot adjust time phase information.
(101183) Fixed tooltips that were not appearing when the user hovered over the related GUI panel.
(100328) Removed uneditable age group and organ selection boxes from the Worker dose results ribbon.
(100329) Disabled custom PSD in PAG Emulation Mode for specific radionuclides. Previously, the general PSD settings could not be changed in PAG Emulation Mode but PSDs could be changed for specific radionuclides.
(101361) Fixed a bug where all daughters in a chain share the same properties object, so that a change to one daughter's properties changed all the daughters in the chain. Now daughter's properties can be changed independently.
(25300) Software files (tfx files) are now optionally included with bug submissions.
(99128) Fixed an error that could occur after recycling a saved calculation and then reopening the recycle bin panel.
(101362) Gas's mass median diameter values are now set to zero.
(101556) Removed the export controlled regulations box from the About panel.
(8774) Created an Interactive Dose Parameter Rollup tool that ranks radionuclides based on their contribution to total dose by dose pathway or mixture total dose.
(99127) Added ability to import RASCAL 4.3.3 source term generated in RASCAL Atmospheric Source Term Merge/Export tool.
(100928) Removed code to unzip files in Windows XP as part of solution to issue where Turbo FRMAC closes when trying to export a calculation.
(101442) Replaced deprecated setSimpleUnitGroup() method calls with the updated version.
(101254) Changed the labels in the PAGs panel in the EPA Water DRL from "CEDE" to "Committed Effective Dose" to reflect correct terminology from ICRP 60.
(100254) The user is now prevented from deleting a currently open calculation.
(22401) Made the panel navigation order consistent in Ingestion calculations.
(12017) Made Human Intake Rates panel titles consistent across Ingestion calculations.
(100597) Fixed bug where EPA Water DRL would sometimes initialize with FDA settings (e.g., FDA radionuclides and missing activity concentration column).
(100373) Changed how an imported mixture would change the mixture type in the Administration of KI calculation to Generic. Now imported mixtures remain the calculation default type of Nuclear Power Plant.
(100454) Improved the text in the instructions tab of the RadResponder Excel export file exported from the AAL calculation with minor edits.
(100524) Fixed an error with parsing calculation files where saved particle size distributions could prevent the files from loading. Now the files load correctly.
(100558) Fixed an error that occurs when the user tries to export a selection in a table to Excel without selecting anything beforehand.
(101305) Added ability to import RASCAL 4.3.4 files, including Source Term vs. Time and Total Surface Concentration by Nuclide from the RASCAL STDose module.
(101341) Changed the result buttons of the time varying Public Protection calculations to be more descriptive.
(101064) Fixed an issue where an invalidly low Time to Harvest input in the Meat DRL and Projected Meat and Milk Contamination calculations was not showing up in the error count displayed on the GUI's notification bar.
(100972) Fixed bug in Projected Meat Contamination calculation that occurred when the user had created one Projected Meat Contamination calculation and then immediately tried to create another one. In this case, only the Activity per Area column would be shown in the radionuclide mixture panel. Now all three value columns are shown correctly.
(100776) ICRP 30 was removed as an ICRP option for the EPA Water DRLs and the Administration of KI calculations because ICRP 30 does not provide the needed dose coefficients for these calculations.
(101520) Fixed the problem that the user defined occupancy factors inputs locked after running a calculation by enabling the occupancy factors input after running a calculation.
(101454) Fixed issue that weathering correction factors panel was not validating values in all time phases if the user selected to have different weathering corrections for different time phases.
(101229) Implemented ability to scale mixtures by a value when Integrated Air Concentrations are the known value.
(101271) Added a note to clarify that the mixture import tool will receive values from Excel in the format that the values are displayed in Excel.
(101487) Added the ability to try to import an unknown version of a RASCAL file in a similar way to the latest version of that file handled by the software.
(101440) Fixed an issue where changing weather factor correction value in one time phase would change the value in another time phase. Now changes only affect a single time phase.
(24625) An update was made to the information displayed to the user that clearly indicates when ICRP values will get reset when the user tries to reset all inputs.
(100919) Fixed that daughter radionculides had different decay constants when a meat or milk contamination calculation was loaded from a save file. Decay constants are now recomputed after opening a save file.
(100690) Expanded the size of the navigation button pane to show warning and emulation mode icons with long button text.
(22707) Disabled age groups other than adult when ICRP 30 is selected for ingestion calculations because the ICRP 30 ingestion dose coefficients only applies to adults.
(24750) Added a horizontal scroll option to the radionuclide mixture properties - radionuclides tab to allow users to scroll through more time phases than the calculations default to.
(100594) Fixed Milk and Meat DRLs to correctly show forage crop type instead of the mistakenly added crop type, leafy vegetable.
(100736) Fixed an error reading projected crop contamination save files, which caused calculation to not load. Now project crop contamination files load calculations correctly.
(100741) Fixed an error in projected crop contamination where flat view only showed the first radionuclide concentration instead of the sum of all instances of that radionuclide. Now the sum of the radionuclide's concentration is shown in flat view in the projected crop contamination calculation
(100893) Fixed how daughter radionuclides were always using the half life of the specific radionuclide, even while in equilibrium, in the contamination calculations. Now daughter radionuclides may use the parent's half life in certain conditions.
SAND2022-14040 W
Turbo FRMAC 11.0.2 (2021)
100956 Log4J2 Vulnerability in TF v11.0.1
A new vulnerability was discovered in Log4J since the release of Log4J v2.16.0. We have since replaced the Log4J library with version 2.17.1, which fixes all known vulnerabilities for Log4J to date.
Turbo FRMAC 11.0.1 (2021)
100801 Log4J2 Vulnerability in Turbo FRMAC 11.0
Installed Log4J library updates, log4j-core-2.16.0.jar and log4j-api-2.16.0.jar, to fix critical vulnerability.
A critical vulnerability was discovered in the Log4J library. The likelihood of this vulnerability being exploited in this application is very low. However, this library existed in the codebase and has been replaced with the patched version issued by Apache. Read further for more details.
Log4J is an open-source logging library used by apps and services across the Internet. Logging is a process where applications keep a running list of activities they have performed, which can later be reviewed in case of error.
The vulnerability is designated as CVE-2021-44228. The vulnerability allows remote attackers to gain control over vulnerable targets. To perform remote code execution, an attacker only needs to send a simple malicious request that contains a formatted string. This formatted string is then picked up by the Log4J library and executed. The result is an attacker's ability to cause Log4j to connect to a service controlled by the attacker to download and execute arbitrary code (likely malicious).
Turbo FRMAC 11.0 (2021)
99762 Implement Analytical Action Levels calculation
Added new Analytical Action Levels calculation based on FRMAC Assessment Manual, Volume 1, Table 4.4-1. This calculation computes Analytical Action Levels using previously-created Public Protection DRL and Ingestion calculations. The new calculation also includes a feature to export the results in a format that can be uploaded to RadResponder by Laboratory Analysis.
44348 Add Building Protection Factors and Occupancy Factors to Worker Protection calculations
Added the Building Protection Factors input panel and the Occupancy Factors input panel to all Worker Protection calculations. Updated the Worker Protection calculations to use these factors.
25405 Allow user to select Imperial or Metric units and date/time formatting
Added ability for user to define how to display units (Imperial or Metric) and format dates and numbers throughout the software. This is particularly useful for international users.
44349 Add the Input Report and Briefing Product buttons to the Worker Protection DRL calculation
Added the Input Report and Briefing Product to the Worker Protection DRL calculation to make it consistent with the Public Protection DRL calculation.
44347 Implement Worker Protection Stay Time calculation
Added new Worker Protection Stay Time calculation. This calculation corresponds to Method 2.1.2 in FRMAC Assessment Manual, Volume 1.
44048 Implement Projecting Contamination Levels in Food calculations
Added three new calculations for projecting contamination in crops, meat, and milk. These calculations correspond to Method 3.6 in FRMAC Assessment Manual, Volume 1.
100075 Add ability to remove FDA Grouped radionuclides from mixture
Added ability to include or exclude any of the FDA Grouped radionuclides from a mixture in Ingestion calculations that use FDA Derived Intervention Levels. This gives users more control over reported results, especially for the new Analytical Action Levels calculation.
44345 Remove multiple dose limits, allow adding Time Phases to Worker Protection calculations
Changed the Dose Limits input from four limits to a single dose limit input and updated the Time Settings input to allow user to add Time Phases. These changes were implemented across all Worker Protection calculations where appropriate and give users more control over reported results, as well as reduces potential user error associated with reporting results for several dose limits at once.
44189 Noble gas daughter deposition velocity incorrectly zero in PAG Emulation Mode
Fixed bug in 1992 EPA PAG Emulation Mode for Public Protection DRL calculations where daughter radionuclides were sometimes assigned incorrect deposition velocities.
25218 Convert Turbo FRMAC to Java 11
Updated Turbo FRMAC to build and run under Java 11.
44047 Remove Hold Time from Ingestion Dose calculations
Removed the Hold Time input from the Solid and Liquid Food Ingestion Dose calculations to be consistent with changes to Method 3.5 in FRMAC Assessment Manual, Volume 1. This removes the decay adjustment from the time between sample evaluation and consumption under the assumption that the level of contamination in the food is at the time the food enters commerce.
44351 Change Fraction of Food Contaminated defaults in Ingestion Dose calculations to 1.0
Changed the "Fraction of Food Contaminated" defaults to 1.0 in the Solid and Liquid Food Ingestion Dose calculations. This change is consistent with the default value specified in Appendix C, Table 11 of FRMAC Assessment Manual, Volume 1.
16556 Provide two Particle Size Distribution inputs for Plume Inhalation and Resuspension Inhalation
Updated all calculations to allow defining two Particle Size Distributions (PSD), one for Plume Inhalation and one for Resuspension Inhalation. This gives users the flexibility to use incident-specific PSD information for the respective exposure pathways. For example, a user might have a modeled-informed PSD for the plume, but still use the default 1-µm assumption for resuspension.
44346 Add Dose Parameter results to Worker Protection calculations
Added the Dose Parameters button to all Worker Protection calculations that use dose parameters. Note that the displayed dose parameters are modified by the Assigned Protection Factor (APF) for respiratory protection and Potassium Iodide Protection Factor (KIPF) where appropriate. The ability to view dose parameters is useful for understanding which exposure pathways and radionuclides are contributing the most to total dose.
99139 Change the Worker Protection default Breathing Rates Panel to reflect Light Exercise
Changed the Worker Protection Breathing Rates panel default input for activity time for Adult Light Exercise to 24 hours so that Activity-Averaged Breathing Rate reflects the default Worker Protection assumption of Light Exercise. Note, this calculation was previously correctly using Light Exercise Breathing Rate for Activity-Averaged but it was not reflected in the GUI, so this change makes this assumption more clear to the user.
SAND2023-03271W
Turbo FRMAC 2020 (v 10.1.2)
44276 Commitment Period query for Acute/Chronic does not work
In Radionuclide Viewer, the Commitment Period dropdown box to select Acute or Chronic did not update when the user selected a new option. Radionuclide Viewer has now been fixed so that it updates the displayed information when the user changes the Commitment Period selection.
100020 Mixture Adjustment Tool Stops Working if Someone Exits Out of the Window and Then Restarts the Tool
Fixed bug where Mixture Adjustment Tool was not functional after exiting out and restarting it.
100021 Mixture Adjustment Tool Allows Blank Input then Errors Later
Fixed bug where Mixture Adjustment Tool allowed invalid inputs and then later produced an error.
100026 Weird Warning in Mixture Adjustment Tool - Seems to Imply that We are Using Values from a Previously-Stopped Input
Removed incorrect warning when launching Mixture Adjustment Tool more than once.
100042 Mixture Adjustment Tool Can Not Open Output File if Excel is Left Open From a Previous Use of the Tool
Fixed bug where leaving Excel open would prevent the user from using the tool the second time.
Turbo FRMAC 2020 (v 10.1.1)
44354 Turning truncation ON resets daughter activity to zero
Fixed issue where turning daughter truncation "ON" would reset daughter activity values to zero.
99684 Include ICRPType Clause in Both Queries for External Dose Coefficients
Fixed issue where query of the dose coefficients was returning the wrong values based on the ICRP Type.
44294 TF2020 freezes on Milk DRL Milk Pathway inputs
Fixed issue where typing in a value for "Time to Harvest" followed by return or tab, caused the application to freeze.
37378 Include latest Assessment Manual updates in TF 2020
Updated the Assessment Manual and Symbol Guide to the July 2020 version.
Turbo FRMAC 2020 (v 10.1.0)
24751 FY19 NIRT Worker Protection
Added new Worker Protection DRL Calculation to match the latest revision of the FRMAC Assessment Manual, Volume1.
23301 Implement Updated Milk DRL Method
Updated Milk DRL Calculation to match the latest revision of the FRMAC Assessment Manual, Volume1.
24824 Add Feed Transfer Factors
Added new transfer factors for feed
25142 Transfer factors updates
Updated default transfer factors to match the latest version of the FRMAC Assessment Manual, Volume 1.
25006 Inadvertent Soil Ingestion Dose
Updated the Soil Ingestion Dose Calculation to be consistent with assumption made in the FRMAC Assessment Manual, Volume1.
22726 Add radio buttons to Crop Pathway Panel to designate crop grown above or below ground
Added a radio button for user to indicate whether crop is growing above or below surface that adjusts the Crop Retention Factor accordingly.
23302 Updated Meat DRL Method
Updated Meat DRL Calculation to match the latest revision of the FRMAC Assessment Manual, Volume1.
25348 Is the MMD and MMAD conversion in PSD wrong?
Updated the MMAD to MMD conversion calculation.
SAND2020-4560 W
Turbo FRMAC 2020 (v 10.0 Beta)
25342 Integrate DCFPAK 2015
Upgraded the radiological database to the latest DCFPAK 2015 database. Six different vintages of data are included, containing published coefficients ranging from years 1983 to 2015. All applications that utilize the DCFPAK data have been modified to read the new data.
25106 Viewing MMD in Particle Size Distribution
Updated PSD table to clearly indicate that the values shown in the table of particle size distributions are aerodynamic diameters.
25205 Change TF Technical Contact Person
Updated the contact person to be Brian Hunt.
23212 User Defined Value in Crop Transfer Factor Table is Lost When Switching to Results.
Corrected issue where a user-defined value in the table of Crop Transfer Factors could be lost when switching to results.
24655 Meat and Milk DRLs show "Crop Type" in the results view
Corrected display where Meat and Milk DRLs previously showed "Crop Type" in the results view. This column now only appears for the Crop DRLs Calculation.
25018 TF Beta Feature Toggle for Deposition Velocity Feature
New Deposition Velocity features have been coded into Turbo FRMAC, but this is not turned on by default. Users can go to Mixture Manager > Tools > Options > Beta Features to enable the Deposition Velocity feature.
23570 Dose Rate and Time Values did not Save
Corrected bug where Dose Rate and Time values were not reloaded when opened from the database.
23417 Refactor Code to Eliminate Multiple Calculation Runner Calls
Improved speed of uncertainty analysis operations by eliminating calls to code that only needed to be performed once per batch.
23166 Update Results to Include the Crop Transfer Factor Source
The Crop DRL result panel shows the Crop Type used in the results for each Radionuclide.
23553 Do not show PSD column for Solid Food Ingestion Dose Calculation
The Solid Food Ingestion Dose calculations no longer show the Particle Size Distribution column.
23566 Nuclear Fallout DRL calculation appears to be incorrect
Implemented corrections for the Nuclear Fallout DRL Calculation.
23571 Nuclear Fallout DRLs Chart does not stretch to fit the width of the pane
Updated the Nuclear Fallout DRLs Chart to stretch to fit the width of the pane.
24626 No Longer Offer FDA Checkbox for Ingestion Dose Calculations
The ICRP Panel in the following Ingestion Dose calculations were updated so as they do NOT show the FDA Checkbox: Solid Food Ingestion Dose, Liquid Food Ingestion Dose, Soil Ingestion Dose.
24635 Change default units for Alpha and Beta TBLs
Changed the default units to uCi/m2 for Alpha and Beta Turn Back Limits.
22510 Multiple occurrences of Dakota tool
Improved window management of the Dakota uncertainty tool.
18316 Need Ability to select a DIL for an FDA Group of radionuclides
Calculates DILs and Ingestion DRLs for the "Grouped Radionuclides" provided by the FDA. When any of the group's members are added to a mixture, the other group members are automatically added. This feature has been implemented for the Cs- and Pu-/Am- groups only; not implemented for the Ru- group.
22463 Add KI Method to Public Protection
Added new "Administration of Kl DRL" Calculation. Calculates the areal or integrated air activity of radionuclides to support decisions to administer Potassium Iodide in response to releases of iodine radionuclides.
SAND2020-2811 W
Turbo FRMAC 2019 (v 9.0.2)
25254 Change the PSD column headers and change the values displayed in the table to the MMAD values
Updated column header text for clarity on Compound Particle Size Distribution panel to clearly indicate the values shown are Aerodynamic Diameter values.
25201 Change default PSD values for Turbo FRMAC
Updated default values for new Lognormal and Uniform Particle Size Distributions.
23545 Turning off truncation resets daughter equilibrium activity to zero if entered as integrated air concentration
Made corrections to ensure that daughter deposition velocities match that of the parent radionuclide after truncation is turned off.
23543 Dakota Runs Taking Longer
Refactored code to eliminate unnecessary repeated calculation calls in batch processing.
23559 New Crop DRL calculation retains user defined inputs from previously created calculation
Corrected issue where the values of a previously selected Crop DRL Calculation were retained when a new Calculation was created.
24813 Change PAG Emulation Mode Particulate Deposition Velocity to 1e-3
Updated default Emulation Mode Particulate deposition velocity to 1e-3 m/s.
SAND2020-2810 W
Turbo FRMAC 2019 (v 9.0.1)
23272 Typo on Import Calculation panel
Corrected a typo on the import calculation panel.
23275 Open via double click on TFX file doesn't work correctly
Corrected problem that allows TFX files to be opened automatically in Turbo FRMAC 2019.
23299 Unable to Open Older TF Versions After Installing TF 2019
Corrected an issue that prevented previous versions of Turbo FRMAC (prior to the 2019 version) from launching, related to reading application settings.
23361 Sluggish performance on the Particle Size Distribution Panel is causing bad results
Corrected a threading issue that sometimes produced incorrect results relating to the Particle Size Distribution settings.
23388 ConcurrentModificationException occurs when clicking calculations when Reset Inputs is in progress
Corrected a threading issue and displays better progress reporting to the user.
23403 Cannot save edited description
Corrected a problem where text area text may not get saved automatically.
SAND2019-4156 W
Turbo FRMAC 2019 (v 9.0.0)
20904 Change Display Name of Infant AgeGroupType
Changed the display name from "Infant (3 months old)" to "3 Months Old" for the AgeGroupType.
21715 MAJOR: Mature and Immature Crop Calculation Update
Updated Crop calculations to match the latest revisions to the FRMAC Assessment Manual.
22192 Cannot Manually Enter Inside Occupancy Factor Initially
Corrected user interface issues for entering Occupancy Factors.
22291 Physical forms reset to particulate after mixture is aged
With this fix, the chemical forms and noble gases are no longer removed following ageing.
22298 Cannot view help videos on TF 64-bit installs and on Mac
Help videos are now viewable on 64-bit versions of Turbo FRMAC and on Mac OS.
22374 The Input Report is hardcoded to the 2017 version
Fixed the Input Report to always reflect the version of the software that produced the report. Previously, it was hardcoded to "2017" which was the first version that included the Input Report.
22452 Combine Mature and Immature Crop Together
Combined Immature Crop and Mature Crop into a single calculation because of their close similarities. The single calculation is now named "Crop". Note that previously calculations created in previous versions of Turbo FRMAC will open in the new version, but values may not be identical due to changes in calculations and default values.
22461 Add Worker Alpha and Beta Turn back limits
Added new Worker Protection Calculation for Alpha and Beta Turn Back Limits.
22593 Update Multiple Forms Help
Improved the Help information for working with Multiple Chemical Forms of Radionuclides.
22641 Changing Units on PAG Panel Does Not Change the Displayed Valid Range
Fixed issue where the range of values allowed on the PAG panel did not change when the units were changed.
22710 Add Mature Root Depth to the Crop DRL Calculation
Added Mature Root Depth as an input to the Calculation.
22713 Cannot Edit Crop Retention Factor
Corrected problem where when you try to enter a different value in the Crop Retention Factor, it doesn't get saved.
22781 The Weathering Correction factor is not staying as I set it while performing a time-varying calculation
Corrected so that the weathering correction is persisting user defined values when switching between calculation and inputs.
22785 ICRP 30 Incorrectly Assigns Deposition Velocities to Xenon
Changed the calculation behavior so that a noble gas's deposition velocity is always 0 regardless of whether multiple chemical forms are supported.
22788 Prevent Special Characters to be used in Time Phase Names
When a calculation is saved to a TFX file, it is saved in XML. If special characters were used (examples: ~!@#$%^&), then it would cause problems creating the XML element names. These special characters are no longer allowed to be used in the names of Time Phases.
23069 TF Hangs on Nuclear Fallout Doses Calculation
Corrected for issues where exceptions could be thrown causing the application to hang up.
23082 Add weathering into soil
Added Weathering inputs to the Soil Ingestion Dose Calculation.
23103 Update the RTG Mixture in Mixture Manager
Created a new RTG mixture called "Plutonium RTG Inventory." The 3 RTG mixtures that previously existed have been removed.
23107 ConcurrentModification on DRL Calculation
Corrected issues related to the threading of running calculations concurrently or attempting to run calculations while inputs could still be saving to the data objects.
23109 Change default worker dose limit on worker Turn back calculations
The default dose limit for Worker Turn-back Calculations have been changed to: 500mrem for Whole Body and 1000mrem for Thyroid
23136 Change Default Result View
All Ingestion Calculations results default to show the "Most Conservative" organ. Other calculations default to show the "Whole Body" organ.
23172 PAG Emulation Mode Problem with Multiple Chemical Forms
When Emulation Mode was turned off, the multiple chemical forms of radionuclides (MCFs) were not being property reconstructed (MCFs are not supported with ICRP30, so in Emulation Mode, you should never see MCFs - only Particulates, or Gas for Noble gases). Also the mixture name was previously lost, but has been corrected.
23187 Change the range minimum to 1.0 for the APF Protection Factors
When the user selects User Defined for Assigned Protection Factor (APF), the minimum allowed value is now 1.0.
23231 Enable Silent Installs for Turbo FRMAC Installers
Added support for silent and unattended installers. IT administrators can use this option for installing Turbo FRMAC on lab computers without requiring step-by-step install interaction and to configure common setups for all computers. Have your IT department contact us at nirp-fogbugz@sandia.gov for usage instructions.
Turbo FRMAC 2018 (v 8.0.3)
22388: Unable to Import TF2018 .tfx File
Corrected problem in the XML parsing code where radionuclide mixtures (.RMIX files) and TF Calculations (.TFX files) could not be opened in the applications.
22390: TF2018 resets in-grown daughters to ZERO and turns off truncation after running calculation
Corrected issue where the Build Mixture panel was unaware of the new truncation setting. Now the truncation setting is properly handled.
Turbo FRMAC 2018 (v 8.0.2)
22376: JavaFX Radionuclide Mixture Pane Not Accessing Concentration Values
Corrected a bug introduced in version 2.202.1 that prevented radionuclide values from being rendered in the newer Java FX tables.
Turbo FRMAC 2018 (v 8.0.1)
22307: Add command to view the log file
Added command under Tools to view the log file.
22334: Update URL for 2018 Release Notes
Fixed URL for release notes which was previously pointing to the 2017 version release notes.
22312: ImageIO Problem with Some Calculations
Reverted changes made to the ImageResource class which caused some calculations on some users' computers to hang up when reading images from the hard drive.
22319: Cannot launch the FDA DILs mixture
If a problem is encountered attempting to read the FDA DILs mixture form the database, a new mixture is created.
22331: NullPointerException CheckForSoftwareUpdateOnline.checkForUpdate
Quietly logs any problem encountered when checking for updates without notifying the user.
22329: Copy to Excel or Clipboard shows N/A for Radionuclide Names
Corrected issue where the radionuclide names in the exported/copied data rendered as N/A.
22310: Update Max Memory on Mac Installer
Increased the maximum memory allocated to Turbo FRMAC from 0.5GB to 4GB. By doing so, this also corrected a problem some users encountered when rebuilding default mixtures in Mixture Manager.
Turbo FRMAC 2018 (v 8.0.0)
21041: Change Default Lung Clearance Type to "Most Likely"
The default Lung Clearance Class for new mixtures is now Most Likely.
22235: Improve Rendering on High-Resolution Displays
Made several improvements to the user interface for better rendering on high-resolution displays.
21025: Rename "Most Likely" to "ICRP Recommended"
Replaced the term "Most Likely" with "ICRP Recommended"
22176: Change default resuspension for worker protection calculations
The new default Resuspension value for Worker Protections was changed to a Constant of 1.0E-5 m^-1.
21954: Change Defults in TF RadionuclideBuildProperties where Truncation Rules = ON by default
A mixture's daughters are truncated by default for new calculations now. Mixtures imported from Mixture Manager will honor the imported truncation setting.
22248: New Return to Grazing Calculations
Added new calculations for Return to Grazing Meat and Milk DRLs. Samples for Mass, Area, and Volume can be entered. New Briefing Products also accompany these new calculations.
7096: Update panel behavior for "User Defined" daily intake rates
Added a reset button that resets the currently selected category of intake rates to their default values. The user is prompted with an explanation and choice to confirm the reset.
21115: Develop DAKOTA Solution in Turbo FRMAC
The DAKOTA Error Analysis Tool is a newly added feature of the Turbo FRMAC software that provides users with the capability of running batches of deposition sample calculations from inputs specified in a structured data input file and sending the results of those calculations to a structured data output file that can then be used as input to other software and processes.
22247: New Projected Public Dose Over Time Calculation
Added a new calculation for Projected Public Dose Over Time along with Briefing Products for this calculation.
20518: Add Water DRL/PAG Calculation
New calculation for Water DRLs have been added to Turbo FRMAC under Ingestion > EPA Water DRLs
21010: Create Public Protection DRLs Input Report
Added new report for the Public Derived Response Levels Calculation.
21260: Deposition velocity not zero for noble gases when use Paste Mixture
Updates the radionuclides when using the Paste Mixture Utility so that noble gases are always given the default deposition velocity of 0, regardless of whether their Chemical Form is set.
21732: Add First Year time phase should have start time of 12 h
When adding new time phases via the toolbar, the correct start time is applied to match the defaults of the calculation.
22168: Cancelling the 'Configure for Each Time Phase' Selection on TF Factors Panels Not Working Properly
Corrected a panel issue where the choice made in the confirmation dialog was not honored when checking the "Configure for Each Time Phase" checkbox on and off.
22137: FDA DILs Freeze Turbo FRMAC in Mature Crop DRL
Fixed application freezing issue with viewing FDA DILs.
22199: Wrong PAG Values for added Time Phases
Corrected issue where adding new Time Phases were not using the same default values as the originally created calculation.
21065: Soil Ingestion Calculation should default to "Activity by Area"
Specified a default Mixture Entry Type for Soil Ingestion Calculations.
21224: Mature Crop Ingestion DRL PAG panel units not shown on Surface Book
On a Microsoft Surface device, the combo box in the PAG panel for the units were not visible. Fixed the panel size to accommodate high-resolution displays.
21225: Resuspension Factor Constant inputs caused "Unrecognized Input" dialogs
Fixed issue where entering a resuspension factor launched "unrecognized input" notifications.
22082: Re-Creating Changing Iodine Deposition Velocities
Corrected issue with assigning deposition velocities to iodine with multiple chemical forms.
22090: checkForComodification Bug for FoodSampleCalculations.calculateRadionuclideIngestionDose
Fixed a threading issue in the Food Sample Calculations that lead to some users getting errors
21642: Incorrect Iodine MCF Deposition Velocity After Change to Lung Clearance Type
Corrected code that was wrongly setting the Composite deposition velocity into the Particulate form of a radionuclide.
21799: Time Varying Calculation locked up while running calculations
Enforces a time phase be selected before calculations can be run on this type of calculation.
21808: Expand and Collapse of Radionuclide Tree Very Slow When a Row is Selected
Eliminated the temporary delay when expanding or collapsing large mixtures.
Turbo FRMAC 2017 (v 7.1.2)
20497: Update the Default Fraction of Diet Contaminated Values
Updated defaults for Fraction of Diet Contaminated for I-131, I-133, Np-239, and Te-132, for 1yr and 3mo age groups; other isotopes of these elements use the normal default of .3 for all age groups.
20891: Inconsistent Results Somehow Related to MCFs
Fixed bug where activity values were being cleared or overwritten in Radionuclides with Multiple Chemical Forms.
20902: Errors In Dose Coefficients and Resulting Dose Parameters for Multiple Chemical Forms (MCFs)
Corrected errors relating to Multiple Chemical Forms; fixed bug where a mixture's 'Keep Existing Values' setting was being ignored.
20928: Dose Parameter Results of the Various MCFs are Copies of the Particulate's Results
Fixed bug where properties of Multiple Chemical Forms were being overwritten with the properties of the Composite Radionuclide.
20929: When Switching to a Generic Mixture, Only Particulate Form is Given a Deposition Velocity
Now using a default deposition velocity of 6.4e-3 for I2 form of Iodine, regardless of mixture type.
20953: TF Freezes on Projected Return Time Calculation on Mac
Fixed issue where the Projected Return Time Calculation would freeze when drawing the charts. This problem only existed on a Mac computer.
20886: Composite Radionuclide Values Not Propagated Down to Associated MCFs
Fixed bug where Multiple Chemical Form values were only set when the MCF dialog was shown.
20872: TF over-rides entered ground concentration data
Corrected logic so that in a mixture where Ground and Air values are known, never reset the deposition velocity to its default value.
21003: Crop Yield value in the Milk_DRL calculation gets reset
Fixed bug where a Milk DRL's Crop Yield value was being reset to default.
21038: More Mixture Properties External Exposure Factors is always 0.0
The External Exposure Factor panel has been hidden from view as a temporary solution while the panel is being updated to be time phase-specific in a future release. In it's previous state, it could present the user with incorrect information if the Evaluation Time was not the same for all time phases.
21043: Nuclear Fallout Freezes on Mac
Fixed issue where the Nuclear Fallout DRLs Calculation would freeze when drawing the charts. This problem only existed on a Mac computer.
20923: Instrument Threshold (Beta Energy Threshold) Changes Not Retained
Fixed bug in DepositionDRL, DRLCurve, LaboratoryDetectionLevels, and WorkerProtection calculations, where changes to the Instrument Threshold value were not being retained.
21013: Update TF Link to FRMAC Assessment Manual
Updated link to the FRMAC Assessment Manual; added FRMAC Documents button in Help->References Ribbon, to view the web page listing links to all available FRMAC references.
20856: TF not consistently populating equilibrium activity for daughters when using the Paste Mixture Utility
Corrected error where daughter values were sometimes being set incorrectly.
20847: Cannot adjust activity time for breathing rates
Corrected error in Breathing Rates panel, where the incorrect timing of the validation check was preventing inputs from being accepted.
20880: Units for the Decay Constant are not shown
Fixed bug where the units selector for a Mixture's Decay Constant or Half-Life was sometimes not visible.
20892: Nuclear Fallout Stay Time Locks Up from Dose Rate and Time Panel
Corrected problem where changing Nuclear Fallout Stay Time inputs sometimes caused TF to freeze.
21011: Missing Units on Mixture Panel When Columns Are Added to the View
Fixed bug where the units selector for a Mixture's Decay Constant or Half-Life was sometimes not visible.
20903: Airborne Particle fraction Units column does not Resize
Corrected column resizing issue in Multiple Chemical Forms dialog.
21068: Check for update hangs on Mac
Fixed an issue that only occurs on Mac computers where checking for software updates could freeze the application.
Turbo FRMAC 2017 (v 7.1.1)
20660: Worker Turn Back Limit Time Phases
Prevents additional time phases from being created for a Worker Protection calculation.
20726: Update TF Splash Screen for HiDPi Screens
Improved rendering of the splash screen on HiDPI devices.
20769: Adding a blank Time Phase has wrong default Evaluation Time
Updated the Blank Time Phase to use a default Evaluation Time of 12 hours. Previously the default was 8 hours.
20771: TF2017 doesn't save user-defined Crop Retention Factor
Fixed bug where entering a value of 0.0 for any crop retention factor value was being reset to the default crop retention factor value.
20760: Access denied & Already in Use Messages
Corrected a server session issue where the user's username and password appeared to be invalid, even though it was successfully logged in.
20767: Calculations Not Being Re-Run for Deposition DRL Calculation
Fixed bug where a DRL Calculation was not detecting when some inputs had been changed by the user, thus not re-running calculations when needed.
20775: MixtureValueEntryType and KnownMixtureValues Radio Buttons Can Get Out of Sync
Fixed bug where settings on the Mixture panel could get out of sync with each other if buttons were clicked too quickly.
20774: Mature Crop Contamination GUI Sometimes Missing Columns and Known Mixture Type Panel
Fixed bug where the Ingestion Contamination Calculations may not always show the necessary columns for entering their mixture information.
20669: MCF Error in Milk and Meat DRL Results
Corrected issue where radionuclides with multiple chemical forms needed to be rebuilt after importing from Mixture Manager.
20709: Turbo FRMAC Web Unable to Launch after Backup
Fixed bug where a file needed for launching Turbo FRMAC Web could become corrupt after a Backup operation and prevented Turbo FRMAC from launching unless the file was deleted and allowed to recreate itself.
20787: Threading Exception Thrown on Turnback Limits Calculation with Large Mixtures
Fixed a recursive loop problem when importing a mixture from Mixture Manager into a Turnback Limits calculation.
Turbo FRMAC 2017 (v 7.1.0)
Improve Launch Speed of Turbo FRMAC Web
In previous versions of Turbo FRMAC Web, some of the files that were needed to launch the Web version needed to be downloaded every time from the website. This is no longer the case and now only updates are downloaded when necessary. This means that subsequent launches of Turbo FRMAC Web will start faster because the files it needs to run have been cached on the user's system and are not re-downloaded unless changes have been made.
Web Login Panel
Turbo FRMAC Web can now be launched without visiting the https://nirp.sandia.gov website in a web browser every time. The first time Turbo FRMAC Web is launched, it creates a shortcut on the user's desktop that, when used, prompts the user to login to Turbo FRMAC Web.
Offline Mode for Turbo FRMAC Web
Without an internet connection, the Web version of Turbo FRMAC will continue to run on the user's computer. This is accomplished by caching the last version of Turbo FRMAC Web that was available when the user last ran it with an internet connection. It is still recommended that users install the Desktop version of Turbo FRMAC if planning to be long periods without an internet connection.
17976: General MCF Improvements for the Users
Miscellaneous updates made to the Multiple Chemical Forms interface for a better user experience.
17852: Retain Previously Saved Partitioning when Importing Mixtures
Now offers the user the option to reset or retain previously entered partitioning values upon import of a mixture from an external source.
11201: Do we still inform users that mixture values are zero?
Added validation rule checking parents for zero ground AND zero air concentrations.
17873: Be able to Read/Import a RASCAL 4.3.1 File
Added ability to import RASCAL v4.3.1 mixture files.
16519: Evaluation Time Not Saved in Nuclear Fallout DRL Calculation
Fixed bug where the Evaluation Time is not saved in a Nuclear Fallout DRL Calculation.
11609: Mixture Error
Fixed issue where imported daughter values were not retained.
17861: Advanced Mixture Properties Panel Does Not Indicate MCFs
The Advanced Mixture Properties panel now renders radionuclides in their different physical forms (if applicable).
17853: MPF Partition sum can be pushed slightly over 1.0 or 100%
Fixed rounding where the multiple chemical form partitioning could display slightly over 100%.
18259: Unable to Display Ribbon in Turbo FRMAC
Fixed bug where some devices with high resolution screens running Windows 8 or Windows 10 could not render the ribbon.
18174: Spelling Mistake: "nuclear" is spelled "nuclar"
Fixed spelling mistake on the "New Calculation" panel where "nuclear" was incorrectly spelled "nuclar".
18305: Change All References to 'Multiple Physical/Chemical Forms' to 'Multiple Forms'
Renamed instances of "Multiple Chemical Forms" to "Multiple Forms."
17978: Enable the PSD button for ANY Particulate, even if part of a Composite (MCF) radionuclide.
Any particulate form of a radionuclide now allows its custom Particle Size Distribution to be edited.
18286: Rename and Reorder Panels for the DRL Calculation
Renamed "constant factors" to "Exposure to Dose Factors". Renamed protection factor to "Ki Protection Factor." Reordered alphabetically.
17923: Dose Rollup Tool losing Dose Parameters on Multiple Physical Forms
Fixed error where values of multiple physical form radionuclides where not included in the Dose Rollup Tool.
18155: Show Weighted Deposition Velocity in Mixture Table Prior to Launching MCF Dialog
Fixed issue where the weighted Deposition Velocity value was not displayed after first importing a mixture.
18312: Creating a New Mature Crop DRL Calculation Throws Exception
Fixed issue where creating a new Mature Crop DRL Calculation could cause the application to hang.
18328: Add Windows compatibility info to TF About Info
Updated information about compatibility with Windows in the About Info.
18073: Use Orange Dot in Icon to Indicate a Custom PSD
When a customized Particle Size Distribution is entered for a single Radionuclide, an orange circle/dot is displayed in the button to indicate so.
18146: Percentage Rounding Not Same for Fraction of Material
Fixed issue when rounding the displayed value of Particle Size Distribution percentage values.
17746: Fix Copy Table Values for Multiple Chemical Forms
Improved rendering of Multiple Chemical Form values when copied from a table to an Excel spreadsheet.
18283: Lung Clearance Type Bug for Non-Particulates
Fixed issue with the Reset button resetting non-Particulate forms of Radionuclide Particle Size Distributions.
17874: Cancel the RASCAL Import Gracefully if Problems Encountered
Improved user experience when a RASCAL file that cannot be imported. User is notified of the problem.
18368: Bug with PAG Emulation Mode Deposition Velocity
Corrected behavior where incorrect Deposition Velocities were set for Radionuclides added to the mixture after PAG Emulation Mode was turned on.
18377: Clicking on or off PAG Manual emulation mode doesn't trigger TF to recalculate
Prevents user from turning EPA PAG Emulation Mode on or off unless they are viewing an Input screen.
18393: When Exiting PAG Emulation Mode, Set ICRP 60 to Enable MCFs
Fixed bug where the ICRP value was not being reset back to ICRP60 after turning off the 1992 EPA PAG Emulation Mode.
18390: Disable Auto-Calculate and Truncate CheckBoxes in PAG Emulation Mode
When in PAG Emulation Mode, the options to toggle "Truncate Decay Chain" and "Auto Calculate Daughters" are disabled to adhere to correct EPA guidelines.
18474: Deposition Velocity/Air/Ground Calculations Not Correct in Mixture Table
Fixed bug where changes to the Deposition Velocity in the mixture table were not triggering the calculation to update Air or Ground Concentration.
18618: Advanced Mix Properties has Units in Wrong Column Because of New "Forms" Column
Fixed displaced location of Units on the Advanced Mixture Properties panel that occurred when Multiple Chemical Forms was added to Turbo FRMAC.
18430: Make the max value allowed: [0, 10] for Exposure to Dose Factors
The maximum value allowed for Exposure to Dose Factors is now 10.
18072: Replace Usage of "Default" for Customized Radionuclides
Clarified terminology of Lung Clearance Classes by using "Master" to indicate that the Calculation's master Lung Clearance Class is used unless otherwise modified for the specific Radionuclide. This eliminates the ambiguous use of the word, "Default".
18251: Calculate Remainder of Fractional Material
Added a command that sets the remainder of unassigned fractional material to the selected Particle Size Distribution.
18405: Check that Time Phase has 1 Dose Pathway Checked
Warns the user if a Time Phase does not have at least one Dose Pathway selected. Otherwise the calculated values for that Time Phase will be zero.
18321: Add Ability to View Release Notes from Update Window
Release Notes can be viewed from the notification that alerts users that new updates are available for the software.
18817: Unable to Run Projected Return Time and Return Threshold Calculations
Corrected a bug that was occurring when a Results button was clicked for a calculation that does not support PAG Emulation Mode.
18805: Should remove Dose Coefficients from "More Mixture Properties"
Dose Coefficients of Radionuclides are no longer displayed on the Advanced Mixture Properties panel of a Calculation.
18877: DRL results do not reflect which physical forms are included in the calculation
DRL Results now indicate how the multiple chemical forms are displayed.
18888: In Time Varying Dropdown, Maxwell/Anspaugh should be first.
Maxwell/Anspaugh Method is displayed first in the list of choices for the Resuspension Calculation Method.
8341: Changing Release Date/Time Back in Time Results in Non-Zero Start Times
Changes in the Release Date will maintain the same existing time offsets in the TimePhases. The Time Phase values will no longer adjust.
18372: Add Label Below Mixture Table Explaining Daughters' Deposition Velocities
When multiple chemical forms exist for a Mixture, a message is displayed explaining how the Deposition Velocity values are determined for the daughter Radionuclides.
16114: Update Default Time Phases to New Values
The default Time Phases for new calculations have been updated to include Early Phase (TD) and Early Phase (AD).
18672: Add Optionally Visible Columns to Mixture Panel
The Mixture Panel can show columns of radionuclide data for the Half-Life, Decay Constant, and Days of Intake (for appropriate calculations). These columns are optionally turned on by the user under the new "View" menu on the Mixture toolbar.
18596: TF 2015 does not add integrated air concentration when mixture is aged
Fixed problem where a Mixture's Air Concentration values were not automatically updated after the Mixture was aged.
18796: Problem with Paste Mixture Utility
Fixed issue when pasting radioncuclides into the Paste Mixture Utility dealing with Multiple Chemical Forms.
11045: RBE Mixture Values Not Saved
Fixed issue where edited RBE values for the Mixture were not retained.
18843: Ingestion Mixtures for Ingestion Calculations Must be Specified by Ground Concentration
Ingestion Mixtures for Ingestion Calculations now only allow mixture entries for Ground Concentration.
18930: Change Limit on Immature Crop DRL Growing Time to 50 Years
Allows a growing time of 50 years for Immature Crop DRL Calculations.
18931: Subset of Ingestion Calculations SHOULD Include MCFs and Allow Values By Air Concentration
Allows user to enter Air Concentrations and support Multiple Chemical Forms in Soil Ingestion Dose Calculations & the 3 Food Contamination Levels Calculations.
18952: Exception exporting when Time Phase name contains parenthesis
Fixed bug that involved exporting a Calculation to a TFX file that contains parenthesis in the name of a Time Phase.
19009: Why Does Search Not Show Results?
Improved the Search Field for searching Radionuclide names.
17869: Handle Upper Bounds of Dose Coefficients
Fixed bug in Uniform Particle Size Distributions where the smallest particle size in the distribution is greater than or equal to the largest dose coefficient record we have in the database. Instead of returning the values that correspond to the largest particle size in DCFPAK, it was previously returning the values for the largest particle size for which it has a valid value. Hence a 100-500 micron distribution is being effectively treated as a 30 micron distribution which is a larger DCF than you’d have for a 10-100 micron distribution.
17907: Add Reset Options Button to Options Dialog
Users can reset the application's options to defaults that are listed under Tools > Options.
17906: Consolidate Last Viewed Directory Code
The directory that the user last viewed when opening any type of file is remembered for the next use.
17895: Application Name and Version Not Appearing in Bug Report Email
Fixed issue where the application's name and version were not appearing in the bug report email.
18762: Retain Window Location on Dual Monitors
When using dual monitors, the location of the application's window is retained. Previously, the application window would always reset back to the monitor designated as Desktop #1 no matter if you had moved it before closing.
16171: Use JavaMail to Send FogBUGZ Messages
Feedback and bug reports can now be submitted silently in the background and no longer requires your personal email client (such as Outlook) to send the email.
18833: Automatically Append the Log File to Submit Feedback Message
Log files are automatically attached to bug reports to aid the software developers in troubleshooting bugs. This can be turned off by unchecking the "Include Error Logs" checkbox.
18914: Show Memory Consumption GUI in Final Versions of Software
Memory consumption components are shown in the bottom right corner of all applications. Previously, this was only shown in beta versions of the software.
18499: Radionuclide Calculations Time Steps vs. Analytical Solution
Increased the number of time steps from 100 to 400 when using the Anspaugh method to calculate DRLs. An Analytical Solution was considered, but not implemented at this time.
18673: Rename ICRP Panel
Renamed the "ICRP Settings" panel to "ICRP Guidance."
19217: Changing units on Return Time results doesn't change graph or table values.
Fixed bug where changing units on a Return Time calculation updated the table of values, but not the chart.
19013: Growing Time Value Lost when Switching ICRP
Fixed bug where the Growing Time Value was lost if the user switched the ICRP value.
19325: Units from drop down menu not fully visible
The Ingestion DRL Results panel allows its table to stretch across the width of the panel now.
19329: Cannot modify crop transfer factor for immature crop DRL calculation
Fixed issue where values were not being retained due to the way event handlers interacted.
18879: Update DIL calculations for FIL methodology
Updated calculations to utilize the FIL methodology for calculating FRMAC Intervention Levels (FILs).
20375: Cannot Change to Monodispersed Coefficient Basis
Fixed issue where if you tried changing the value from Lognormal to Monodispersed for the Inhalation Coefficient Basis, it would not let you select the other value.
20396: Warning not needed for a DIL calculation
Prevents an informational message from being displayed to the user that didn't make sense when only entering names of radionuclides and not values.
20478: Correct Advanced Mixture Properties Panel in Intervention Levels
Removed the "Days of Intake" table column from the Advanced Mixture Properties panel.
20516: Windows 10 Compatibility
Improved software compatibility with Windows 10.
19010: Clicking FDA DILs Button froze TF
Added a means of rebuilding the missing default mixtures so that users can correct this problem if it happens to them.
20499: Meat Transfer Factor Oddity
Corrected the default Beef Transfer Factor value for the following Radionuclide families: Al, Ar, At, Bk, C, Es, Fm, Fr, Ge, H, Kr, Lu, Md, Ne, O, Pt, Rn, Ti, Tm, V, Xe, Yb
19256: Exports Data Files to Temp Directory
Fixed Export to default to user docs folder.
19276: New Database Install Does Not Setup Automatic Proxy Settings
Updates to the default proxy.
System Requirements
Operating System | Designed and tested on Windows 11; Expected to be compatible with Windows Vista, 7, 8, and 10, though not formally tested; Expected to function in certain virtual environments, but not tested. |
Minimum Requirements | |
CPU | 2GHz Pentium 4 |
Memory | 2GB RAM |
Disk Storage | 30GB Free |
Monitor Resolution | 1280 x 1024 or Higher |
Recommended Requirements | |
CPU | Dual- or Quad-Core of higher |
Memory | 4GB RAM or higher |
Disk Storage | 50GB Free or higher |
Monitor Resolution | 1280 x 1024 or higher |
SAND2020-7966 W